ZEUS has implemented a new second level trigger based on 12 dual-CPU PCs which use tracking information from the new microvertex detector (MVD, see above), the central track detector and the new forward straw tube tracker. The mean processing time is 10 - 15 s at an input rate of about 300 Hz, as determined by the first level trigger.