The following example shows a set of tagger in the forward/backward region.
They sit at z 180 cm, between a radius of 135 and 152 cm. The energy
is poor: the relative error is 150%/. The efficiency is 95 %,
and the threshold is 1.0 GeV. The type of the taggers is 1, hence they
will detect photons and electrons as showers. Since parameters are given for
minimum ionising detection, such particles will also be detected, with
an average signal equivalent to what a 1.0 GeV shower would deposit.
The threshold for mips is 1.0 GeV, and the efficiency is 45 %. Note
that charged hadrons will also be seen as mip's.
It is modular in
and R (SHOWER_POS_MEAS=1), with 12 modules
in
and one in R. The first module starts at 15.0 degrees.
TYPE: FORWARD_TAGGERS LAYER:TAG GEOMETRY: Z=180.0, RMIN=135.0, RMAX=152.0 MATERIAL: X0=3.6 , A= 98, INTLEN=0.12 MEASUREMENT: TYPE=1,ROOT_E_COEFF=1.5, CONST_TERM=0.0 EFFI=0.95,THRES=0.5, SHOWER_POS_MEAS=1, NCELL1=12, NCELL2=1, PHI_FST_CELL=15.0, MIP_AVE_SIGN=1.0, MIP_SIGN_WIDTH=1.0, MIP_THRES=1.0, MIP_EFF=0.45